Impedance Calculator

Impedance describes the total opposition that an electrical circuit presents to alternating current.

Unlike ordinary resistance, impedance includes both resistance and reactance. Reactance is introduced by inductors and capacitors, and its value changes with operating frequency.

The Impedance Calculator helps you analyse AC circuits containing resistors, inductors and capacitors. Choose a series or parallel arrangement, enter the component values and frequency, and obtain the complex impedance, magnitude and phase angle.

The calculator also displays inductive and capacitive reactance separately, helping you understand whether a circuit behaves predominantly as an inductive or capacitive load.

Load Example:
Series RLC Circuit|Z| = 265.927130702 Ω, φ = --67.91°
AC SourceCurrentRLCTotal Impedance: 265.927130702 Ω ∠ --67.91°
Impedance Phasor DiagramPhase Angle: --67.91°
R (Ω)+jX (XL)−jX (XC)Z
Complex Impedance (Z)Net Capacitive (current leads voltage)
100 − j246.4087 Ω
Polar: 265.927130702 Ω ∠ --67.91° • |Z| = 265.927130702 Ω • Phase = --67.91°
Impedance Magnitude (|Z|)
265.927130702 Ω
Phase Angle (φ)
--67.91°
Real Component (R)
100 Ω
Reactive Component (X)
—
Inductive Reactance (XL)
18.849555922 Ω
Capacitive Reactance (XC)
265.258238486 Ω
Power Factor
0.376 leading
Circuit Behaviour
Net Capacitive (current leads voltage)

Note: This calculator analyses lumped AC RLC circuits and does not calculate transmission-line characteristic impedance.

  1. 1ω = 2πf = 2π × 60 Hz = 376.99112 rad/s
  2. 2X_L = ωL = 18.849555922 Ω
  3. 3X_C = 1 / (ωC) = 265.258238486 Ω
  4. 4Series: Z = R + j(X_L − X_C) = 100 − j246.4087 Ω
  5. 5|Z| = 265.927130702 Ω, φ = --67.91°, PF = 0.376 leading

What Is Electrical Impedance?

Electrical impedance is represented by the complex quantity:

Z = R + jX

Where:

  • Z is complex impedance.
  • R is resistance.
  • X is net reactance.
  • j is the imaginary unit.

The real part represents resistance, while the imaginary part represents reactance.

Impedance is measured in ohms (Ω).

How to Use the Calculator

  1. Select Series or Parallel.
  2. Enable the components present in your circuit.
  3. Enter resistance, inductance and capacitance.
  4. Enter the operating frequency.
  5. Select the appropriate units.
  6. Optionally enter an RMS source voltage.
  7. Calculate the result.
  8. Review impedance magnitude, phase, reactance and the phasor diagram.

Inductive Reactance

An inductor opposes changes in alternating current.

X_L = 2πfL

Inductive reactance increases when frequency or inductance increases.

Capacitive Reactance

A capacitor opposes alternating current according to its capacitance and operating frequency.

X_C = 1 / (2πfC)

Capacitive reactance decreases as frequency or capacitance increases. Check component markings with our Capacitor Code Calculator.

Series RLC Impedance

In a series circuit, the same current flows through the resistor, inductor and capacitor.

Z = R + j(X_L − X_C)

If inductive reactance is greater than capacitive reactance, the circuit behaves inductively.

If capacitive reactance is greater, the circuit behaves capacitively.

When the two reactances are equal, their reactive effects cancel. Explore this condition directly in our LC Resonance Calculator.

Parallel RLC Impedance

In a parallel circuit, each branch is connected across the same source voltage.

Y = 1/R + 1/(jωL) + jωC,   Z = 1/Y

Parallel impedance must be calculated using the sum of complex admittances.

This is why the series impedance equation cannot simply be reused for a parallel circuit.

Worked Example

Consider a series RLC circuit with R = 100 Ω, L = 50 mH, C = 10 µF, f = 60 Hz.

Inductive reactance: X_L = 2π(60)(0.05) = 18.85 Ω

Capacitive reactance: X_C = 1 / [2π(60)(10 × 10⁻⁶)] = 265.26 Ω

Net reactance: X = 18.85 − 265.26 = −246.41 Ω

Therefore: Z = 100 − j246.41 Ω

Magnitude: |Z| = √(100² + (−246.41)²) ≈ 265.93 Ω

Phase angle: φ = atan2(−246.41, 100) ≈ −67.91°

The negative phase angle indicates a capacitive circuit.

Applications

Impedance calculations are useful in:

  • AC circuit analysis.
  • Audio amplifier circuits.
  • Passive filters.
  • Resonant networks.
  • Power electronics.
  • Electronic instrumentation.
  • Signal conditioning.
  • RLC circuit design.

Common Mistakes

  • Confusing resistance with impedance.
  • Ignoring operating frequency.
  • Using the wrong unit for inductance.
  • Confusing series and parallel equations.
  • Ignoring the imaginary component.
  • Using an ordinary resistance formula for complex impedance.
  • Confusing lumped-circuit impedance with transmission-line characteristic impedance.

Important Limitation

This calculator analyses lumped electrical AC circuits.

It is not a PCB microstrip, coaxial cable, differential-pair or transmission-line characteristic impedance calculator. Those require additional physical geometry and material parameters.

Real components also have ESR, parasitic inductance, parasitic capacitance and frequency-dependent losses.

Frequently Asked Questions

1. What is the difference between impedance and resistance?

Resistance is the real opposition to current. Impedance includes resistance and frequency-dependent reactance.

2. What is inductive reactance?

It is the opposition an inductor presents to AC, calculated using frequency and inductance.

3. What is capacitive reactance?

It is the opposition a capacitor presents to AC, calculated using frequency and capacitance.

4. Why is impedance a complex number?

Because AC circuit resistance and reactance have different phase relationships.

5. What does a negative phase angle mean?

It indicates net capacitive behaviour, where current leads voltage.

6. Why does frequency matter?

Inductive reactance increases with frequency, while capacitive reactance decreases.

7. Can impedance be calculated for parallel RLC circuits?

Yes. Calculate the total complex admittance first, then take its reciprocal.

Conclusion

The Impedance Calculator provides a practical way to analyse series and parallel AC circuits. Its complex impedance calculations, reactance results and phase visualization help users understand how resistance, inductance, capacitance and frequency affect circuit behaviour. Continue exploring related tools: LC Resonance Calculator, Capacitor Code Calculator, RC Filter Calculator, RC Time Constant Calculator and Ohm's Law Calculator.

Explore companion electronics and circuit calculators for component decoding, DC/AC analysis, filtering, timing, and RF design.